EASA has ordered more frequent functional checks of pressure regulator and shut-off valves in the de-icing systems of specified ATR 42 and ATR 72 aircraft, citing the possibility of an undetected failure leading to loss of control in icing conditions. Airworthiness directive 2026-0219 takes effect on 30 November and supersedes a January 2025 directive, tightening recurring maintenance requirements across the covered fleet.
The directive applies to ATR 42-200, -300, -320, -400 and -500 models and ATR 72-101, -102, -201, -202, -211, -212 and -212A aircraft. The valves control and shut off the air supply to the de-icing system; a dormant fault may not become apparent until the aircraft encounters icing.
Check intervals depend on aircraft model and modification status. The directive assigns groups intervals of 190, 210 or 160 flight hours, with additional transitional limits governing when those recurring intervals apply. Operators must follow the group-specific compliance rules rather than apply a single interval across the fleet.
If a check identifies a discrepancy, corrective action must be completed before the aircraft’s next flight. Where ATR’s maintenance instructions do not address the fault, operators must obtain approved instructions from the manufacturer and carry them out. The revised requirements follow updated ATR maintenance information, including Issue 6 of its maintenance document, dated 26 October 2026.