EASA has issued an airworthiness directive requiring more frequent functional checks of pressure regulator and shut-off valves in the de-icing systems of specified ATR 42 and ATR 72 aircraft. The rule covers ATR 42-200, -300, -320, -400 and -500 variants and ATR 72-101, -102, -201, -202, -211, -212 and -212A aircraft of all serial numbers. It takes effect on 30 November and supersedes a directive issued in January 2025.
Under AD 2026-0219, repeat checks are required at intervals of 190, 210 or 160 flight hours, depending on aircraft group and modification status. Transitional provisions determine when the shorter intervals begin to apply and cap the time to the next check. Any discrepancy found must be corrected before the aircraft’s next flight; if the maintenance instructions do not provide a remedy, operators must obtain approved instructions from ATR.
EASA’s design review identified a risk of dormant valve failures. If such a fault remains undetected and the aircraft encounters icing conditions, de-icing performance could be compromised, potentially resulting in loss of control. The revised requirements replace the previous inspection intervals, requiring affected operators to adjust maintenance planning.